Skip to content
adiPowerby Adimyra Systems
Explore

A page for every job at the pump

Features in detail

  • Shift and nozzle reading software
  • Tank dip and fuel stock software
  • Tanker receiving and decantation register
  • Petrol pump credit customer software
  • Petrol pump billing software, works offline
  • UPI and card reconciliation for petrol pumps
  • Daily petrol and diesel rate changes
  • 5-litre test, density and licence registers
  • Petrol pump owner dashboard app
  • Petrol pump website with today's rates
  • Lubricant and shop stock software
  • adiBOOK
  • adiHRMS

Who it is for

  • Software for a single petrol pump owner
  • Multi-outlet software for petrol pump chains
  • Petrol pump manager app
  • Petrol pump accounts for CAs
  • Software setup for a new petrol pump
  • Software for dealers of any oil company
  • Petrol pump register and Excel vs software
  • Is accounting software enough for a petrol pump?

Guides

  • How to calculate petrol pump sales from nozzle readings
  • How to read a tank dip chart, step by step
  • Petrol pump density check at 15°C explained
  • 5-litre measure test at a petrol pump
  • Petrol pump stock variance: causes and control
  • GST for petrol pumps: what is taxed and what is not
  • Petrol pump staff salary with PF and ESIC
  • How to manage petrol pump credit customers
  • Closing a petrol pump shift and matching cash
  • Petrol pump manager's daily checklist
  • Registers a petrol pump keeps: a checklist
  • Petrol pump guides for owners and managers

Pricing and company

  • adiPower home
  • Plans and prices
  • Start 15-day free trial
  • Live demo
  • Sign in
  • About adiPower
  • Contact sales and support
  • Security and data protection
  • Questions owners ask (FAQ)
  • Terms of service
  • Privacy policy
  • Refunds and cancellation

See the whole map →

Features
  • All features
  • Shift and nozzle reading software
  • Tank dip and fuel stock software
  • Tanker receiving and decantation register
  • Petrol pump credit customer software
  • Petrol pump billing software, works offline
  • UPI and card reconciliation for petrol pumps
  • Daily petrol and diesel rate changes
  • 5-litre test, density and licence registers
  • Petrol pump owner dashboard app
  • Petrol pump website with today's rates
  • Lubricant and shop stock software

Other apps

  • adiBOOK
  • adiHRMS
Who it is for
  • Software for a single petrol pump owner
  • Multi-outlet software for petrol pump chains
  • Petrol pump manager app
  • Petrol pump accounts for CAs
  • Software setup for a new petrol pump
  • Software for dealers of any oil company

Compare

  • Petrol pump register and Excel vs software
  • Is accounting software enough for a petrol pump?
Guides
  • All guides
  • How to calculate petrol pump sales from nozzle readings
  • How to read a tank dip chart, step by step
  • Petrol pump density check at 15°C explained
  • 5-litre measure test at a petrol pump
  • Petrol pump stock variance: causes and control
  • GST for petrol pumps: what is taxed and what is not
  • Petrol pump staff salary with PF and ESIC
  • How to manage petrol pump credit customers
  • Closing a petrol pump shift and matching cash
  • Petrol pump manager's daily checklist
  • Registers a petrol pump keeps: a checklist
Pricing
  • Plans and prices
  • Start 15-day free trial
  • Live demo
  • Sign in
Company
  • About adiPower
  • Contact sales and support
  • Security and data protection
  • Questions owners ask (FAQ)

Legal

  • Terms of service
  • Privacy policy
  • Refunds and cancellation
हिन्दीSign inStart free trial
Home/Guides/Density at 15°C
Density at 15°C

Density check at a petrol pump, and why 15°C matters

Fuel expands when warm, so its density depends on temperature. To compare a sample with the density on the tanker invoice, convert the observed density at the observed temperature to density at 15°C using the standard petroleum tables; a large difference can mean adulteration or a wrong product.

By the adiPower team, Adimyra Systems · Published 5 November 2026 · Facts checked 5 November 2026

How the check is done

  1. Draw a sample into a clean jar and let air bubbles clear.
  2. Float the hydrometer and read the density where the fuel surface meets the scale.
  3. Read the sample's temperature with the thermometer.
  4. Convert to density at 15°C with the petroleum measurement tables (Table 53B for fuels).
  5. Compare with the invoice density at 15°C and record both.

Oil companies set how much difference is allowed; a figure of up to 3 kg/m³ is commonly used for petrol and diesel. Check your own company's current guideline, and do not decant a load that falls outside it before speaking to the company.

Read next

  • Tanker receiving and decantation register

    Record tanker invoices, dips before and after decantation and density, and get a shortage report before the tanker leaves.

  • 5-litre test, density and licence registers

    Petrol pump registers on a phone: 5-litre test, density, licences with reminders, safety checks and the complaint book.

  • How to read a tank dip chart, step by step

    Take a dip, check for water and read litres between two rows of the calibration chart, with a worked example.

Run tonight's shift on adiPower

Set up tanks, nozzles and today's rates in the trial, or open the demo first.

Start 15-day free trialTry the live demo
adiPower

adiPower, adiBOOK and adiHRMS are products of Adimyra Systems Private Limited.

adimyra.com · care@adimyra.com

Product

FeaturesLive demoPricingStart free trialSign in

Features

Shifts and nozzle readingsTank dips and stockTanker receivingCredit customersOffline billingRegistersadiBOOK: books and GSTadiHRMS: payroll

Solutions

Single outletChainsManagersCAsNew outletsOil company dealersvs register and Excelvs accounting software

Guides

All guidesSales from nozzle readingsReading a dip chartGST for petrol pumpsStaff PF and ESIC

Company

AboutContactSecurityFAQ

Legal

TermsPrivacyRefunds and cancellation

© 2026 Adimyra Systems Private Limited. All rights reserved.