The 5-litre measure test at a petrol pump
The 5-litre test checks that a nozzle delivers what its meter shows: dispense into a certified 5-litre measure and read the difference on its neck scale. Under the weights and measures rules the permissible error is commonly ±25 ml on 5 litres; the fuel goes back into the tank and is not a sale.
By the adiPower team, Adimyra Systems · Published 5 November 2026 · Facts checked 5 November 2026
How to do it
- Use a clean, stamped 5-litre measure on level ground; wet it once and drain it.
- Preset or dispense exactly 5.00 litres on the dispenser.
- Wait for the foam to settle and read the neck scale at eye level.
- Record the nozzle, the reading, the difference in ml, the time and who did it.
- Pour the fuel back into the same tank and record it as testing.
A customer may ask for the test at any time, and the outlet should do it. Outlets usually test every nozzle at the start of the day as well.
Confirm the current tolerance and register format with your state's Legal Metrology department and your oil company.